| This Lind Rugged DC/DC Adapter meets the most common MIL-Standards, usually required in many military applications, as well as other industrial environments. | | TECHNICAL INFORMATION |
| |
|
| | DC Input Characteristics; |
| | Input | 11 to 32 VDC | | EMI/RFI Characteristics: | meets MIL-STD461E, CE102, CS101, CS114, CS115, CS116, RE102, RS101, RS103 | | Input transient Protection: | meets MIL-STD-1275D, Voltage Surge +100 VDC, Voltage Spike +/-250 VDC | | Low Input Voltage Shutdown: | Auto Recovery | | High Input Voltage Shutdown: | Auto Recovery | | Load Dump Protection: | meets ISO 7637 | | Reverse Polarity: | | | DC OUTPUT CHARACTERISTICS; |
| | Short Circuit Protection: | | | Isolation Voltage: | Input to Output nonisolated, 100 VDC output to case | | Noise and Ripple: | meets MIL-STD-1275D and MIL-STD461E CE102 | | PHYSICAL AND ENVIRONMENTAL SPECIFICATIONS; | | | | | Operating Temperature: | -40 to +60 DegC | | Storage Temperature: | -40 to +80 DegC | | High Temperature: | meets MIL-STD-810F, method 501.4 | | Low Temperature: | meets MIL-STD-810F, method 502.4 | | Temperature Shock: | meets MIL-STD-810F, method 503.4 | | Shock: | meets MIL-STD-810F, method 516.5, proc. I | | Acceleration: | meets MIL-STD-810F, method 513.5, proc. I, Helicopters | | Vibration: | meets MIL-STD-810F, method 514.5, proc. I, Category 20 Ground Vehicles | | Humidity: | meets MIL-STD-810F, method 507.4 | | Salt and Fog: | meets MIL-STD-810F, method 509.4 | | Sand and Dust: | meets MIL-STD-810F, method 510.4 | | Enclosure: | Extruded Aluminum | | Finish: | Black anodized | | Weight: | 32 oz | | Dimensions: | 9.3 x 3.0 x 1.3 in | |